Acid gases and condensate
HF (from LiPF6 and moisture), acid mist, NOx where thermal oxidizers run
- What it attacks
- Carbon steel, galvanized and glass. Stainless too, once condensate forms.
- How the material answers
- 304/304L in dry service. 316L where condensate is likely. Confirm against your chemistry.
- How the weld answers
- Continuous full-penetration welds leave no laps or crevices to hold condensate, and a leak-tight run keeps humid air out.